http://www.goldminingcentre.com.au

|
The Magnascanner MS3500 is designed to give Maximum Security
with minimum maintenance. This heavyweight champ is built to withstand outside weather
conditions of all sorts, or rough handling anywhere. And yet give reliable screening at
all times. The Magnascanner MS3500 was designed specifically to stand up to the everyday
demands of jails, prisons, mental hospital and other facilities requiring rugged
reliability.
Magnascanner MS3500:
-Is completely weather resistant.
-Constructed with 3/32" armour aluminium with mar resistant end caps.
-Assembled with tamper-proof screws for complete abuse-resistance.
-Uses microprocessors in both the detection and control circuitry.
-Gives uniform coverage-from head to toe-for precise target evaluation.
-Offers excellent sensitivity, stability and noise rejection.
-Is easy to set up and operate, with few adjustments required.
-Has an optional desk top control unit for use in remote operations.
-Secured and tamper-proof controls, using digital access codes.
-Has completely modularized electronics for serviceability.
-Optional battery pack.
-Offers three levels of ankle-boost sensitivity. |

(Afforded super-human powers through the use
of a Garrett Super Scanner) |
Regulating and Operating Displays
- LCD Display: Large alpha/numeric display on the
Control Panel reports (in words) all regulating, controlling and self-prompting functions
of the unit.
- Self-Prompting: Because the unit is designed to be
"user-friendly," all regulation and control functions are self-prompting with
necessary commands shown on the LCD display.
- Ready Light: This green light appears when full
power has been turned on and the unit is ready to detect. The light will also indicate
when an individual inspection has been completed by the unit and it is ready to accept the
next person
- Alarm Light: This red light appears when the unit
detects a target amount of metal on an individual, according to specifications of the
Program and Sensitivity levels. This light will appear even when sound volume has been
turned off.
- Bar Graph: This LED display indicates the detection
intensity which is based on the amount and composition of metallic objects passing through
the unit.
Eight touchpads on the Control Panel below the LCD display
on the archway perform all control functions.
- Standby: When this touchpad is pressed, the unit
goes into a low power mode, ready to be returned to full operation instantly when the
OPERATE pad is touched.
- Operate: When this touchpad is pressed, full
detection power of the unit is turned on. It also initiates an automatic and comprehensive
self-test and diagnostic program for instant fault detection. Touching this pad at any
time activates the testing procedure. If faults are found, they will be immediately
reported on the LCD display.
- Counter: When this touchpad is pressed, the current
traffic count for the unit is shown on the LCD display. Pressing and holding this touchpad
for ten (10) seconds causes the counter to return to zero (0).
- Volume: When this touchpad is pressed, the volume
level of the unit s audio alarm will be displayed on the LCD display. By using the + and
touchpads, operators can raise or lower the volume.+and: These touchpads will be used to
increase or decrease various numerical settings and for certain On/Off functions.
- Program: When this touchpad is pressed, the settings
for Program and Sensitivity will appear on the LCD display.
All of the above touchpad functions are available to
operators of the detector
Access: This touchpad will be used only by
supervisory management personnel. It permits changing the Program and Sensitivity codes
and also is used to control such functions as synchronisation of multiple units, pulse
frequency and tone. The unit further protects security of control settings by maintaining
a non-resettable sequence code that indicates any attempt at seeking access to the
settings. A tamper alarm sounds within 10 seconds after the Access touchpad is pressed
unless proper access code is entered.
Technical Specifications
- Electronics: Digital-controlled pulse induction
metal detector with microprocessors utilised in both detection and control circuitry.
Designed for tailoring specific programs to fulfil various security applications.
Electronics are modular and designed for easy plug-in and change.
- Program levels: Ultimate versatility, 20 standard
programs. Designed for tailoring specific programs to fulfil various security
applications.
- Self diagnostic: Whenever unit is turned on,
self-test of all systems is performed automatically with any failures or problems reported
on the LCD display.
- Ankle boost: Multiple coil design provides three
intensity levels of ankle-boost sensitivity to insure uniformity of screening in all
security applications.
- Sensitivity:1-200 per program for precise target
selection.
- Memory: All program selections and settings are
maintained in electrically erasable non-volatile memory. The unit will maintain all
settings even when disconnected from power. No battery is required for memory retention.
- Overhead control unit: LCD Display, LED bar graph
and control touchpad plus all wiring, connections and electronics are integrated in a
single overhead compartment; eliminates exposed wires and external control box.
- Control outputs: Solid state switches (low voltage
AC or DC) for operating external alarms and control devices.
- Indicators: Ready light indicates unit is
operational; Alarm light and audible alarm are activated when target amount of metal is
detected; LED bar graph indicates amplitude of alarm signal.
- Traffic counter: Built-in and resettable with
current reading easily available on LCD panel.
- Tamperproof: Dual-level access codes required to set
or change all sensitivity settings and detection programs; one level for use by
supervisors in selecting programs and sensitivity and the other for initial set-up and
overall control; non-resettable sequence code logs all changes made whenever sensitivity
codes are accessed. Audible alarm reports any unauthorised attempt at access.
- Construction: 3/32" Armour Aluminium cladding;
control panel and cross pieces of heavy duty aluminium.
- Regulatory information: Meets or exceeds detection
requirements of the National Institute of Law Enforcement and Criminal Justice Standards
#0601.00, levels 1-5, and Federal Aviation Administration airport application
specifications. Programs have been designed specifically to meet the three-gun test of the
FAA and requirements of the Undetectable Firearm Act of 1991.
- Also complies with IEC standards for Safety requirements for
Electronic Measuring Apparatus and meets the Federal Communications Commission Class B
standards for noise emission from commercial electrical equipment.
- Public Safety: The peak magnetic field strength of
less than one Gauss will not affect magnetic recording media, including magnetic tape,
diskette and cards. Unit has been tested in accordance to and meets the electromagnetic
safety requirements of:
- -Institute of Electrical and Electronics Engineers: A Standard of
Safety Levels with Respect to Human Exposure in Radio Frequency Electromagnetic Fields, 3
kHz to 300 GHz" IEEE C95.1 -1991 section 4.12.
- -Occupational and Safety Health Administration: Radiation Protection
Guide, CFR 1910.97 section (2)i.
- -National Institute of Law Enforcement and Criminal Justice:
Standards for Walk-Through Metal Detectors for use in Weapons Detection, NILECJ-STD-0601
.00 section 4.11.
- -Canada Health and Welfare Performance Standards (Walk Through),
RPB-SC-18 8 section 3.2.2 which addresses the issue of electromagnetic effects to cardiac
pacemakers.
- Infrared sensor: Improves analysis of detection
signal; increases throughput; helps eliminate "false alarms," also provides
accurate traffic counter.
- Interference rejection: 100% sensor coil Faraday
shielding; special Garrett built-in circuitry for noise suppression and ignoring x-ray
monitor horizontal sync.
- Masking: Microprocessor programming designed to
eliminate the problem of detection signals from two or more targets cancelling each
other.Synchronisation: Multiple frequencies permit several Magnascanners to operate
simultaneously in close proximity.
- Electrical: Fully automatic 85 to 265 VAC, 50 or 60
Hertz, 5 watts; no rewiring, switching or adjustments required. Power supply meets UL,
CSA, TUV, and VDE Standards.
- Operating temperatures: -4F (-20C) to + 158F (70C)
- Humidity: To 95% non-condensing.
- Throughput rate: Not limited by electronics; 50-60
detections per minute is reasonable.
Optional features:
- 2225700 Battery back-up allows up to 20 hrs.
- 2225600 Remote Control Console - allows remote operation up to 50
feet.
Weight: Approximately 200 pounds (91 kg).
Model: 1167200
Dimensions:
| Passageway interior |
Overall exterior |
Shipping: |
| Width 30" (0.76 m) |
Width 35" (0.9 m) |
Width 33.5" (85.1 cm) |
| Height 80" (2 m) |
Height 87" (2.2 m) |
Height 91.5" (223.4 cm) |
| Depth 23" (0.57 m) |
Depth 23 (0.57 m) |
Depth 6.25" (15.9 cm) |
| |
|
Weight 136 lbs. (61.8 kg) |
©Copyright to Gold Mining Centre®
All Right Reserved - 1999, 2000 |